Structural Remediation of Strip Mall Canopy


Customer

Wolf Shopping Center

 

Location

 

Wolf Road, Des Plaines, IL

 

Symptom

 

Canopy structure originally built with insufficient load bearing capacity.

 

Problem

 

Canopy pulling away from building superstructure and tilting downward.

 

Structural

Solution

 

Shored and jacked up canopy to level position. Installed steel beams and columns along entire 125 ft length of strip mall canopy. Mounted columns in steel reinforced concrete footings. Wrapped columns in brick and installed EIFS along entire length of beam line. Removed roof over canopy and replaced the ineffective framing with structurally sound framing secured to building superstructure. Installed new modified bitumen roofing.


Shored and Jacked canopy into level position
Installed new beams
125' beam line
Installed steel columns with steel reinforced concrete footings
Wrapped columns in brick
Wrapped beam line in stucco
Existing roof over canopy
Demolition of roof and framing over canopy
Prepared canopy for new framing
Installed new framing for canopy
New canopy center piece
Installed new modified bitumen roof
Completed Project

 

Conversion of Non-usable Basement Space into Revenue Generating Addition to Pub

Doubled Usable Space at a Chicago Night Club via Basement Dig-out and Pouring of a New Steel Reinforced Foundation Slab with Perimeter Retaining Walls.


Customer

New Lotties Pub

 

Location

Chicago, IL, (Bucktown Neighborhood)

 

Structural

Solution

Doubled space and capacity of nightclub by digging out basement and pouring 10” steel reinforced concrete slab with steel reinforced integrated retaining walls to support the existing foundation. Installed steel columns and back entrance concrete stairway with steel reinforced CMU retaining walls. The photos below, as shown from left to right, show the project progression.


Start of Basement Dig-out
Laid Gravel
Laid Steel Rebar
Set Retaining Wall Forms
Forms Removed
Open for Business!

 

Replaced Wood Beams and Columns with Steel


Customer

Dino's Restaurant

 

Project Location

Higgins Ave. Chicago, IL

 

Problem

Unsafe sagging floors due to deteriorated wooden beams and columns.

 

Structural

Solution

Replaced deteriorated wood beams and columns with steel beams and columns. The steel columns were set in steel reinforced concrete footings.


Steel columns mounted on steel reinforced concrete footings
Steel reinforced footing
Steel beam and column mounted to foundation

 

Failed Precast Concrete Planking Remediation


Customer

Strip Mall

 

Location

Rolling Meadows, IL.

 

Problem

Defective and Unsafe Concrete Precast Planking (used for structural floor of strip mall)

 

Structural

Solution

Installed steel beams and columns under areas of defective precast concrete planking used for floor in strip mall. Set columns in steel reinforced concrete footings.


Beam and column installation
Columns mounted in steel reinforced concrete footings
System supports precast concrete planking
 

 

Installed Emergency Shoring and Repaired Structure


Customer

Hot Dog Richies' Restaurant

 

Location

 

Palatine, IL

 

Problem

 

Vehicle struck overhead garage doors and area between doors.

 

Structural Solution

 

Provided temporary emergency shoring followed by the installation of a steel column between overhead garage doors. For future protection, installed protective posts in front of the column and the other two sides of overhead doors. Set column and protective posts in steel reinforced concrete and finished center column in stucco.


Provided temporary emergency shoring and installed steel column.
Completed job with protective posts and finished center column with stucco.